Typical Performance for LEM-200

The upper line of figures for each voltage refers to the maximum current at which the motor can run continuously at that voltage without overheating, under the following conditions:

Ventilation good, but not assisted by an external fan.

The motor is clean and will maintained.

The brush holder is adjusted to the optimum position for this load (which means that the motor must not be run at full load in the reverse direction unless it is fitted with means to move the brush holder when the direction of rotation is reversed).

             

Voltage

Current

Power input

Power
output

RPM

Efficiency

Torque

V

A

KW

KW

Speed

%

Nm

12 100 1.2 0.87 580 72 14.4
12 45 0.54 0.445 675 82 6.2
24 140 3.36 2.7 1300 80 20
24 70 1.68 1.45 1415 86 10
36 170 6.12 5.17 2060 84 24
36 80 2.88 2.6 2200 90 11.3
48 200 9.6 8.4 2925 86 28
48 90 4.32 3.95 2970 91 12.8
60 200 12 10.6 3650 89 28
60 90 5.4 5 3750 92 12.8

48 volt maximum for applications requiring long term durability

The lower line of figures for each voltage refers to the current at which maximum efficiency is achieved on this voltage. Ideally the motor should normally run at about this current.
Maximum current for 5 seconds is 400 amps at any voltage. For competition where greater current is required please consult Lmc Ltd, as certain modifications are advisable.

For applications involving long periods of running without maintenance the normal running current should not exceed 60% of the "maximum continuous" figure for the relevant voltage. This also applies where full-load operation in both directions is needed, unless a device is fitted to move the brush holder to the optimum position in each direction

Advantages

Applications

High Efficiency
(Reduced Power Consumption)
Scooters
Longer Battery Life
Motorboats/Saildrives
Simple Control Lightweight
Electric Cars
Light Weight Design
Golf Cars
Power to Weight Ratio
Go-Karts
Pancake Design
Floor Sweepers
High Torque at Low Speed Grass Cutters
  Pumps
  Welding Generators

Please consult LMC LTD about any generator application.

Back To Top of Page Button

Uses of L.M.C. Motors - INDUSTRAIL, LEISURE, HYBRID, COMPRESSOR
Designed by Project COSMIC
Link opens in new window
Lynch Motor Company Ltd, Unit 8 Park Court, Heathpark, Honiton, Devon, EX14 1SW
Tel +44 (0) 1404 549940, Fax +44 (0) 1404 549546 Email: sales@lmcltd.net